1 Voltage
Charging voltage DC: 8.4V CC/CV
Balance voltage for single cellInput Voltage - 0.3V~+10V
2 Current
Balance current for single cell
Current consumption Max: 16.00µA
Maximal continuous charging current 4A
Maximal continuous Discharging current 4A
3 Over charge Protection
Over charge detection voltage for single cell 4.28V ± 0.05V
Over charge detection delay time 0.8 ~ 1.2S
Over charge release voltage for single cell 4.08 ± 0.1V
4 Over discharge protection
Over discharge detection voltage for single cell 2.8V ± 0.1V
Over discharge detection delay time 80 ~160ms
Over discharge release voltage for single cell 3.0 ± 0.1V
5 Over current protection
Over current detection current 7~15A
Detection delay time 7 - 20ms
Release condition cut load
6 Short protection
Detection condition Exterior short circuit
Detection delay time 100-350us
Release condition cut load
7 Resistance Protection ≤ 30mΩ
8 Temperature
Operating Temperature Range -20 ~ +60°C
Storage Temperature Range -20 ~ +65°C