top of page

Product Descriptions

 

15S40A 48V LFP Battery Management system (BMS) is designed specifically for lithium-iron Phosphate batteries pack of 48V. It can measure, collect, process and use the information data of the battery in real time and ensure the safety and stability of the battery.

15S40A 48V LFP BMS has following salient features

  • The protection of batteries from over-charge, over-discharge, over-current, short-circuit
  • Short term water proof to protect battery pack from extreme weather and tough dynamic conditions.
  • Common Port design - 2 wires only, Charge and discharge port share the same port.
  • BMS comes with balancing connection wire connector to reduce the wire complexity and number of solders.
  • Dust proof, shockproof and anti-squeezing, protects circuit from external damages.
  • BMS has passive balancing function which gives long life to the batteries.
  • The appearance is sealed by injection moulding process to improve moisture-proof and oxidation-proof circuit components and prolong the service life of the products and batteries.

15S40A 48V LFP BMS

₹1,590.00Price
  • Battery Management System for 48V 15S40A battery pack configuration of Lithium Iron Phosphate cells.

    Over Charge Protection: Yes

    Over Discharge Voltage: Yes

    Short Circuit Protection: Yes

    Cell balancing Yes

    Over Current Protection Yes

    BMS Size 80X61X12 mm (LXWXH)

    Specification:-

    Discharge

    Continuous Discharging Current 40A

    Over discharge Current Detect Voltage 100±20A

    Charge

    Charging Voltage 54.75V

    Charging Current 20A

    Over charge protection

    Over Charge Protection Voltage 3.75±0.05V

    Release delay of Single Over Charge Protection 1S

    Over Charge Release Voltage 3.55±0.05V

    Cell balancing

    Cell balancing Detection Voltage 3.5V

    Cell balancing Current 30±5mA

    Over discharge protection

    Over Discharge Detect Voltage 2.2±0.05V

    Over discharge Detect Delay Time 1S

    Over Discharger Release Voltage 2.7±0.05V

    Charge/Discharge Overflow protection

    Discharge Current Level 2 Protection Current 100±20A

    Discharge Current Level 2 Protection delay 1S

    Over Current Protection Condition Disconnect the load

    Short Circuit Protection

    Protection Condition Short circuit of External Load

    Detection Delay Time 250 uS

    Protection Release Condition Disconnect the load

    Temperature Range -20ºC ~ 60ºC

    Internal Resistance ≤20mΩ

May be interested in

bottom of page